Case Report

Digital Workflow in Oral Implantology: A Case Report

Naroa Lozano-Carrascal1, Rafel Rodríguez-Bauzá2 and Oscar Salomó-Coll1*
1Department of Medicine and Dentistry, International University of Catalonia (UIC), Spain
2International University of Catalonia (UIC), Spain


*Corresponding author: Oscar Salomó-Coll, Department of Medicine and Dentistry, International University of Catalonia, Carrer de Josep Trueta s/n, 08195 Sant Cugat del Vallés, Barcelona, Spain


Published: 20 Sep, 2018
Cite this article as: Lozano-Carrascal N, Rodríguez-Bauzá R, Salomó-Coll O. Digital Workflow in Oral Implantology: A Case Report. J Dent Oral Biol. 2018; 3(6): 1147.

Abstract

Implants ideal 3D position and inclination are mandatory to obtain optimal aesthetic outcomes with long-term stability. Digital work-flow in oral implantology offers: Implant 3D planning with the possibility of printing a surgical stent , digital impressions and a printed model, 3D abutments design and finally manufacturing all-ceramic restorations with milled-ceramics. 28 year-old patient attended to the practice because of 2.1 horizontal fractures after a head-trauma. Atraumatic extraction of tooth 2.1 and socket preservation was carried out under local anesthesia an Astra TX implant (Astra Tech, Densply, Sweden) was placed, simultaneous guided bone regeneration was performed. Digital intraoral impression scanner was taken with scanning-abutment Core Scan body was performed. A custom-made abutment and a full-ceramic crown were made for the final restoration.


Introduction

Implant restorations for partially or totally edentulous patients have become a highly predictable treatment, however restoration success is not based only on implant osseointegration whether the aesthetic result [1,2]. Implants ideal 3D position and inclination are mandatory to obtain optimal aesthetic outcomes with long-term stability its essential to design and manufacture structures and individualized abutments that mimic natural teeth and adapt to the characteristics of each patient providing the necessary support to the peri-implant tissues [3-5]. A defective restoration due to lack of adjustment, can lead to mechanical or biological complications or even the failure of the restoration and the implant, compromising the long-term functional and aesthetical outcomes. Main advantages of digital work-flow in oral implantology are: Implant 3D planning with the possibility of printing a surgical stent to optimize implant position, changing conventional impressions by digital impressions reducing the dimensional variations and obtaining a printed model, the possibility of designing 3D abutments that allow to support soft-tissue around implant and finally manufacturing all-ceramic restorations with milled-ceramics [5]. The objective of this publication is to show the wide variety of possibilities that digital work-flow offer in oral implantology through the explanation of a case report.


Case Presentation and Discussion

Patient of 28 years attended to the Department of Oral Implantology of the International University of Catalonia because of mobility in 2.1 after a head-trauma. After clinical and radiological examination through periapical X-ray and CBCT (Cone Beam Computed Tomography) scan nonrestorable root fracture of tooth 2.1 was diagnosed (Figure 1). Due to the high aesthetic demands and the thin buccal plate, it was decided to perform the traumatic extraction of the 2.1 and to perform a ridge preservation of the alveolus to place a single implant after the healing period.
Atraumatic extraction of tooth 2.1 was carried out and the alveolus was preserved following the Ice-Cone technique described by Elian et al. [6], using a collagen membrane (Bio-guide, Geistlich Biomaterials, Parma, USA) and Xenograft (Bio-Oss, Geistlich Biomaterials, Parma, USA), later on membrane exposure was covered with soft tissue graft obtained from the palate fixed with single sutures and finally provisionalized with Maryland bridge (Figure 2).
After 6 months healing (Figure 3) impressions were taken to confection a diagnostic wax-up, and then a radiological splint. After the CBCT Scan, implant planning was performed with MGuide Software (MIS Implants Technologies, Israel) (Figure 4).
Under local anesthesia a 4 per 10 mm. Astra TX implant (Astra Tech, Densply, Sweden) was placed, due to the poor availability of bone an implant dehiscence was created in the buccal area, simultaneous bone regeneration was performed with Xenograft (Bio-Oss, Geistlich Biomaterials, Parma, USA) and membrane (Mem-Lok, Bihorizons, Birmingham, USA) (Figure 5) [7]. As high implant primary stability was not achieved patient continued with the Maryland Bridge during the healing period.
Six months after implant placement, a connective tissue graft harvested from tuberosity was performed to improve soft tissue contour around implant. A traumatic second surgery was performed using the provisional Maryland Bridge that the patient wears during healing period by the progressive addition of filling material [8]. When implant shoulder was reach a screwed-retained temporary provisional was made with a titanium abutment and composite crown, temporary restoration was modified until the desired emergence profile was achieved (Figure 6).
For the definitive restoration, a digital intraoral impression scanner LAVA C.O.S (3M ESPE, Spain) with scanning-abutment Core Scan body (Avinent®-CORE 3D, Spain) was performed. This system required that the impression surfaces must be isolated from fluids and dusted with a light coating of titanium dioxide powder. Powder point’s help to inter-relating the video images captured by the sensors, with these images high-quality 3D surfaces at real time are generated. While the images are captured, a digital model is obtained in the virtual screen of the scanner. The scan of the 2.1 area was performed, followed by the scan of neighboring teeth or working arch, opposite arch and finally the scan of the bite was carried out (Figure 7).
Once the images of the digital impression were inspected and approved, were transmitted electronically to the online laboratory in “STL” format. The design of a zirconia abutment with a titanium interface was performed by the software of CAD design of 3 Shape (3 Shape, Denmark) (Figure 8), files were sent to the milling center (Avinent®, Spain), for the milling of the structure on the one hand, and on the other, the prototype model or milled model was printed with an 3D Eden 260V (Sistemas Objet, Israel) printer, utilizing a composite injection technique. The restoration material for the crown was IPS E-Max Ceram (IvoclarVivadent AG, Liechtenstein) (Figure 9).


Figure 1

Another alt text

Figure 1
Initial situation of 28-year old woman, with high smile line and nonrestorable root fracture of 2.1: (a) frontal view; (b) periapical radiograph at baseline; (c) axial slice of the Cone Beam Computed Tomography scan.

Figure 2

Another alt text

Figure 2
Frontal view after tooth extraction with the provisional Maryland Bridge.

Figure 3

Another alt text

Figure 3
Clinical situation 6 months after the socket preservation: (a) frontal view; (b) lateral view; (c) occlusal view.

Figure 4

Another alt text

Figure 4
Computer-assisted implant planning of 21 performed with MGuide Software.

Figure 5

Another alt text

Figure 5
(a) Occlusal view of the crest before the implant placement surgery; (b) Surgical stent for the Three-Dimensional (3D) implant placement; (c) Situation of the implant after correct 3D position; (d-e) Contour augmentation with desproteinized bovine bone mineral and covered with a resorbable collagen membrane; (f) The surgery was completed by tension-free primary wound closure.

Figure 6

Another alt text

Figure 6
Soft tissue management: (a) frontal view with implant-screw provisional restoration; (b) frontal view if the emergence profile; (c) occlusal view of the emergence profile.

Figure 7

Another alt text

Figure 7
Digital file “STL” obtained from the digital intraoral impression.

Figure 8

Another alt text

Figure 8
Zirconia abutment with a titanium interface designed by CAD software.

Figure 9

Another alt text

Figure 9
Frontal view at 1-year follow-up.

References

  1. Fürhauser R, Florescu D, Benesch T, Haas R, Mailath G, Watzek G. Evaluation of soft tissue around single-tooth implant crowns: the pink esthetic score. Clin Oral Implants Res. 2005;16(6):639-44.
  2. Belser U, Buser D, Higginbottom F. Consensus statements and recommended clinical procedures regarding esthetics in implant dentistry. Int J Oral Maxillofac Implants. 2004;19:73-4.
  3. Phillips K, Kois JC. Aesthetic peri-implant site development. The restorative connection. Dent Clin North Am. 1998;42(1):57-70.
  4. De Lange GL. Aesthetic and prosthetic principles for single tooth implant procedures: An overview. Practical Periodontics Aesthetic Dentistry. 1995;7:51-61.
  5. Ramsey CD, Ritter RG. Utilization of digital technologies for fabrication of definitive implant-supported restorations. J Esthet Restor Dent. 2012;24(5):299-308.
  6. Elian N, Cho SC, Froum S, Smith RB, Tarnow DP. A simplified socket classification and repair technique. Pract Proced Aesthet Dent. 2007;19(2):99-104.
  7. Jensen SS, Terheyden H. Bone augmentation procedures in localized defects in the alveolar ridge: Clinical results of different bone graft and bone substitute materials. Int J Oral Maxillofac Implants. 2009;24:218-36.